I share with you a  case of unstable fracture neck femur. He is 33 years old. 
He has been operated at the same day of trauma. Cannulated screws fixation technique with inverted triangle configuration was used. 

After one year the fracture is completely united with full range of motion of the right hip joint except for loss of last degrees of internal and external rotation.
He has good functional outcome without pain. 

Several studies show that Inverted triangular configuration showed the mechanical advantage and being less likely to cutout. 

X rays of right hip postoperative and after 1 year of follow up show complete union of unstable fracture neck femur that has been fixed by 3 cannulated screws with inverted triangle configuration. The graphic design picture shows the lateral view of inverted triangle configuration.